FASEB J. Pierce now sold as Thermo Scientific
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolf, L. E.
Right arrow Articles by Ezrailson, E. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolf, L. E.
Right arrow Articles by Ezrailson, E. G.

The FASEB Journal, Vol 7, 1265-1268, Copyright © 1993 by The Federation of American Societies for Experimental Biology


RESEARCH COMMUNICATIONS

Human immune response to polydimethylsiloxane (silicone): screening studies in a breast implant population

LE Wolf, M Lappe, RD Peterson and EG Ezrailson
Plaza Medical Center, Houston, Texas 77004.

Although initially it was thought that polydimethylsiloxane (silicone) was biologically inert, recent published studies have demonstrated varying levels of IgG antibody reactive with this structure in humans. The objective of our study was to determine whether silicone implanted in humans results in a measurable immune response directed against a 3700 mol wt hydroxyl terminated silicone molecule and whether that response could be correlated with the level of presumed silicone exposure as inferred by clinical history. In a blind study, sera from 111 patients, with and without breast implants, were sent to a laboratory using an enzyme-linked immunosorbent assay to determine specific anti-silicone IgG antibody levels. Test results showed that patients with implants demonstrated statistically significant elevation in anti-silicone antibodies compared with the unimplanted control groups. The highest anti-silicone antibody levels were measured in implanted women with either frank implant ruptures or leakage of their silicone gel implants.


This article has been cited by other articles:


Home page
Rheumatology (Oxford)Home page
B. Jensen, A. Wiik, I. Hechmann Wittrup, S. Friis, G.-Q. Shen, H. Bliddal, J. K. McLaughlin, B. Lykke Thomsen, B. Danneskiold-Samsoe, and J. H. Olsen
Silicate antibodies in Danish women with silicone breast implants
Rheumatology, September 1, 2003; 42(9): 1032 - 1035.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
S. Lu, G. A. Rouse, and M. De Lange
Sonoographic Detection of Silicone Breast Implant Rupture
Journal of Diagnostic Medical Sonography, January 1, 1995; 11(1): 3 - 8.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1993 by The Federation of American Societies for Experimental Biology.