|
|
||||||||
Tissue Engineering Center, University Department of Surgery, Royal Free and University College Medical School, University College London and The Royal Free Hospital, London, UK
2Correspondence: University Department of Surgery, Royal Free and University College Medical School, University College London, The Royal Free Hospital, Pond Street, London NW3 2QG, UK. E-mail: A.Seifalian{at}RFC.UCL.AC.UK
Tissue engineering of endothelial cells (EC) and chemical engineering with anticoagulant moieties has been undertaken in order to improve prosthetic graft patency and thrombogenicity. This was done by covalently bonding a compliant poly(carbonate-urea)urethane graft (MyoLinkTM) with arginine-glycine-aspartate (RGD) or/and heparin (Hep) to ascertain whether EC retention could be improved. The retention of these moieties and EC was assessed after exposure to pulsatile flow. We covalently bonded RGD, Hep, and RGD/Hep onto the luminal surface of MyoLink using spacer arm technology. Narrow-beam X-ray photoelectron spectroscopy was carried out to check the efficiency of the bonding. EC were radiolabeled and seeded onto native MyoLink and with 1) RGD-, 2) Hep-, and 3) RGD/Hep-bonded grafts and exposed to shear stress in a physiological flow circuit for 6 h, which reproduces femoral artery flow waveforms and pulsatility. Results were recorded on a gamma camera imaging system. Viability of cells was tested with a modified Alamar Blue assay (ABA) and scanning electron microscopy for morphological appearance of seeded cells. Experiments were repeated (n=6). RGD, Hep, and RGD/Hep were bonded together in a uniform distribution on the luminal surface of each graft type, and bioactivity of each moiety covalently bonded was very high. In the flow circuit, there was exponential cell retention for the first 60 min of flow for all the grafts, but after 6 h of exposure to pulsatile flow the RGD/Hep-bonded graft had a significantly better cell retention rate than native MyoLink (75.7%±2.3 vs. 60.5±10.1, P<0.05). ABA test showed that all the seeded cells postexposure to flow were viable, and significantly higher metabolic activity was recorded on a RGD/Hep-bonded graft than with MyoLink-seeded graft (P<0.01). Using RGD/Hep covalently bonded onto graft surfaces improves cell retention and provides an antithrombogenic surface for initial blood flow in vivo until full EC activity develops postseeding. This would allow the development and further improvement of hybrid grafts.Tiwari, A., Salacinski, H. J., Punshon, G., Hamilton, G., Seifalian, A. M. Development of a hybrid cardiovascular graft using a tissue engineering approach.
Key Words: hybrid graft anticoagulant peptide endothelial cells spacer arm covalent bonding x-ray photoelectron spectroscopy
This article has been cited by other articles:
![]() |
S. T. Rashid, B. Fuller, G. Hamilton, and A. M. Seifalian Tissue engineering of a hybrid bypass graft for coronary and lower limb bypass surgery FASEB J, June 1, 2008; 22(6): 2084 - 2089. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Turner, M. O. Murphy, C. M. Kielty, C. A. Shuttleworth, R. A. Black, M. J. Humphries, M. G. Walker, and A. E. Canfield {alpha}2(VIII) Collagen Substrata Enhance Endothelial Cell Retention Under Acute Shear Stress Flow via an {alpha}2{beta}1 Integrin-Dependent Mechanism: An In Vitro and In Vivo Study Circulation, August 22, 2006; 114(8): 820 - 829. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. Thakrar, V. P. Patel, G. Hamilton, B. J. Fuller, and A. M. Seifalian Vitreous cryopreservation maintains the viscoelastic property of human vascular grafts FASEB J, May 1, 2006; 20(7): 874 - 881. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M. Nugent and E. R. Edelman Tissue Engineering Therapy for Cardiovascular Disease Circ. Res., May 30, 2003; 92(10): 1068 - 1078. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |